Re: What is the net output of Rotax's internal generator?
by Philip Box » 3 hours ago
With all the discussion around the voltage regulator/rectifier I expect that to be my problem.
Re: What is the net output of Rotax's internal generator?
by Sean Griffin » one hour ago
Hi Phil
"With all the discussion around the voltage regulator/rectifier I expect that to be my problem. "
Check out the VR diagnostic article I sent you
https://pointsforpilots.blogspot.com/2012/12/testing-rotax-912914-generator-and.html
😈
Re: What is the net output of Rotax's internal generator?
by Rotax Wizard » one hour ago
This info is only found in the installation manual. The system has a max of 250 watts, about 22Amps. The best advice is found in AC 43-13 current edition (FAA) so you should not draw more than 80% of your total output, so just under 18 amps. Do a load test of all your electrical draw to see how you fit into that formula.
Cheers
|