1. If the ring mount is the standard and best mounting interface for the 912, then why ship the engine with a water pump outlet tube that interferes with the ring mount. Why not deliver the engine with the 80˚ elbow installed? (I did order and install the elbow.)

2. The radiator inlet and outlet and the expansion tank outlet tubes are all ≈25.4 mm in diameter. The water pump inlet is 27.5 mm. Why? Does everyone just wrestle with a 1" hose to make it fit the water pump inlet? Do you use a larger clamp on it?

John

  • Re: New 912 Install: Coolant sys gripes

    by » Yesterday


    I don't remember any wrestling with the water pump inlet hose.


  • Re: New 912 Install: Coolant sys gripes

    by » 21 hours ago


    Hi John,

    Speculation:

    1. While the Ring Mount may be  considered "The Standard" many other mounting systems are "out there". If Rotax were to deliver engines with the water pump in/outlets in another configuration, someone else would likely complain - ie its a no win situation.

    2. Like James I have never had a problem fitting 1" ID hoses to my 912. There is enough elasticity in the hose to accomodate 27.5mm.

    😈


  • Re: New 912 Install: Coolant sys gripes

    by » 7 hours ago


    The water pump fitting can be turned right or left and  at different angles. It should work for any installation. I do a ton or rubber changes and have enevr had an issue. The only issue I have sometimes is with how close the firewall is and muffler that can make it a little harder to get the hoses on, but it works out when you get more experience. 


    Roger Lee
    LSRM-A & Rotax Instructor & Rotax IRC
    Tucson, AZ Ryan Airfield (KRYN)
    520-349-7056 Cell